Buckskin /
BollardLights
2026-10-17, Saturday
Worked on Bollard #15 today
- Working the base mounting screws loose was VERY difficult. I gave up on using ball-end hex wrenches, since they popped out too often, and frankly, I could see that I was rounding the corners of the wrench's hex head.
- Went to Ace Hardware and purchased a combination SAE+Metric set of straight-headed hex wrenches which proved to be much better. The 3/16" wrench fitted the KOBALT hex wrench handle just fine and it had a firmer grip on the sunken socket in the bolt head
- Was able to unscrew 3 of the mounting bolts, two without too much effort, but at first the third was locked tight, as was the fourth bolt, and eventually I was able to jog the screw just enough to then begin working back and forth and at last working the bolt all the way out.
- Learned a few key things today:
- The base mounting bolts can be unscrewed all the way out with the threads showing until at last the bolt drops free
- Bollards with the ballast intact, and with at least one of the four bolts screwed in, cannot be removed, cannot be tipped so that the reticent bolt is disengaged from the base plate. With the bollard in place, it prevents the bollard body from tipping to the side enough to release from the fourth bolt that is screwed in.
2026-10-16, Friday
Worked with bollard lights further today.
- Further research and hands-on efforts have determined that the top cap is secured with 3/32" hex head bolts, and the body mounts the base using 3/16" hex head bolts
- Bollard #12 (counting from top)
- Was, at last, able to un-do four bolts at the bottom, after much effort using my new T-handle mounted hex wrench
- Lo, the ballast has been removed!, and an LED bulb is inside.
- The wiring has the usual BLACK, WHITE that are uncut and simply loop from the upstream conduit to the downstream conduit. The GREEN wire, and RED wires coming from upstream, and RED wires going downstream.
- The light socket's BLACK and WHITE wires are tied to each of the RED wire junctions under Blue wire nuts.
- With the RED wires un-wire-nutted and separated, I found that there appeared to be a short between the upstream pair, and the downstream pairs! I read 0-ohms with this test. Hmmm.
- I re-attached the light socket's BLACK and WHITE leads to the appropriate upstream RED wires, leaving the downstream wires disconnected.
- Bollard #9 (counting from top, the "problem child")
- After the changes to wiring on Bollard #12, I reconnected the upstream BLUE wires to the downstream BLUE wires to allow power to reach Bollard #9
- The ballast assembly that was removed in May was left 'out' (still under garage bench), but I connected the pigtail from the ballast assembly to the upstream/downstream connection wire nuts, and the ground wire from a ballast body bolt to the GREEN wire nut.
- Pigtail was originally connected to the ballast transformer:
- pigtail BLACK to transformer BROWN/BLACK
- pigtail WHITE to transformer WHITE [COM]
- ground wire GREEN from ballast U-bracket
- Pigtail was originally connected to the ballast transformer:
- Powered the circuit, and found that bollards #10 and #11 lighted! The circuit didn't shutdown, popping the breaker so the trouble isn't with #9, #10, #11, or #12.
- I borrowed the LED bulb from #3 and replaced the LED bulb in #12; Lo!, it worked. So the original LED bulb in #12 is bad.
- I also tried the LED bulb from #3 in #9, and lo!, it worked there too!
- So, we are now lighted all the way from #1 to #12, except that new/additional LED bulbs are needed for #4 and #12, with the #4 LED bulb was left in #9.
- #9 also needs a new screw-on glass lens over the bulb; and #4 has a cracked lens so it should be replaced. A little web searching suggests that these are called 'jelly jars' and there are sources for potential replacements online, including Platt Electric.
2026-09-27, Sunday
Worked on bollard lights today
- Lithonia Hi-Tek (Lithonia Lighting), KBR8-100S-LV-240, mfg. date 12-03-1997 (in bollard that is not mounted to base), uses bulb type S54
- Using that information learned that the top cap is secured by 3 stainless screws with 3/16" hex head, and body mounts to base using four (4) 1/4" hex bolts
- Looked at each bollard light (except white ones), going from house down to gate:
- #1 (white, at shop turnaround)
- #2 (white, at gateway)
- #3 has an LED bulb: Light Efficient Designs, LED-8037E345-A 11W 120-277Vac 50/60Hz 0.09W (photo) set for 3000K color
- #4 Won't light, bulb looks okay; unable to unscrew base screws, very tight, need to use a penetrating oil
- #5 Top removable after using 3/16 hex to loosen, base tight
- #6 Top removable, base tight
- #7 Top removable, cannot remove bulb cover too tight, base tight
- #8 Top removable, base tight
- #9 Our problem child
- This is the one that has fallen over several times, all four of the screw brackets normally welded on the inside of the body are missing! No way to secure it to the base like that.
- The ballast assembly is presently removed (in garage under bench), having been removed by Ben from Travelling Brothers Electric in May
- An idea for solving the mounting problem:
- use stainless bolts long enough to go through each of the bollard body holes, but still extend out
- put a nut on the inside to secure and stabilize the bolt prior to securing it
- perhaps a solid plastic block could be placed on the bolt, that is sized to contact the concrete pier, this way any downward force from the bolt being tightened would tend to pivot on the inner lower edge and also apply downward pressure on the bollard body, too
- #10 Unable to remove top, base is a little loose
- #11 Top removable, base secure, another LED bulb same as #3
- #12 Top removable, base secure, tightened the screws a bit, unable to remove them
- #13 Top removable, base secure
- #14 Unable to remove top, base secure
- #15 Top removable, base secure, unable to loosen
- Northern gate enclosure
- Wall Junction Box (photo)
- Power arrives at the junction box over Red, Yellow, Black, White, Green wires
- RED goes to Northern enclosure lights (this on)
- YELLOW goes to Southern enclosure lights via large flat grey ROMEX (doesn't use RED conductor)
- BLACK goes to gate control via a yellow ROMEX
- WHITE ties all Commons together
- GREEN ties all Grounds together
- Floor sprinkler junction box
- TBD
- Wall Junction Box (photo)
- Southern gate enclosure
- NEEDS a junction box
- wires are weathering, but not shorting out (yet!)